Welcome to Shenzhen Sing Fung Intelligent Manufacturing Co., Ltd.
E-mail:shaobo@sfi-crf.com
Tips for distinguishing between radio frequency plasma cleaner and intermediate frequency plasma cleaner
- Categories:Industry News
- Author:Plasma cleaning machine-CRF plasma plasma equipment-plasma surface treatment machine manufacturer-chengfeng intelligent manufacturing
- Origin:
- Time of issue:2021-12-16
- Views:
(Summary description)Tips for distinguishing between radio frequency plasma cleaner and intermediate frequency plasma cleaner: The intermediate frequency plasma cleaner is an intermediate frequency. The 40KHz intermediate frequency power supply uses 16-bit microprocessor as the core, power electronic devices as the power output unit, and adopts new technologies such as digital frequency division, phase lock, waveform instantaneous feedback, SPWM pulse width modulation, IGBT output, etc. , And adopts a modular structure, with strong load adaptability, high efficiency, good stability, good output waveform quality, simple operation, small size, light weight, intelligent control, abnormal protection function, adjustable output frequency, fast output response , Strong overload capacity, fully isolated output, long life, good damage resistance. This kind of power controller is used on intermediate frequency ion equipment. RF plasma cleaners use RF power, that is to say, the difference between our intermediate frequency plasma cleaner and RF plasma cleaner lies in the matching power they use. RadioFrequency, or RF for short. RF is RF current, which is an abbreviation for alternating high-frequency electromagnetic waves. The alternating current is called low-frequency current when it is below 1000 per second, and it is called high-frequency current when it is above 10000. The radio frequency current is this kind of high-frequency current. Therefore, we will easily distinguish between these two types of equipment.
Tips for distinguishing between radio frequency plasma cleaner and intermediate frequency plasma cleaner
(Summary description)Tips for distinguishing between radio frequency plasma cleaner and intermediate frequency plasma cleaner:
The intermediate frequency plasma cleaner is an intermediate frequency. The 40KHz intermediate frequency power supply uses 16-bit microprocessor as the core, power electronic devices as the power output unit, and adopts new technologies such as digital frequency division, phase lock, waveform instantaneous feedback, SPWM pulse width modulation, IGBT output, etc. , And adopts a modular structure, with strong load adaptability, high efficiency, good stability, good output waveform quality, simple operation, small size, light weight, intelligent control, abnormal protection function, adjustable output frequency, fast output response , Strong overload capacity, fully isolated output, long life, good damage resistance. This kind of power controller is used on intermediate frequency ion equipment.
RF plasma cleaners use RF power, that is to say, the difference between our intermediate frequency plasma cleaner and RF plasma cleaner lies in the matching power they use. RadioFrequency, or RF for short. RF is RF current, which is an abbreviation for alternating high-frequency electromagnetic waves. The alternating current is called low-frequency current when it is below 1000 per second, and it is called high-frequency current when it is above 10000. The radio frequency current is this kind of high-frequency current. Therefore, we will easily distinguish between these two types of equipment.
- Categories:Industry News
- Author:Plasma cleaning machine-CRF plasma plasma equipment-plasma surface treatment machine manufacturer-chengfeng intelligent manufacturing
- Origin:
- Time of issue:2021-12-16 21:53
- Views:
Tips for distinguishing between radio frequency plasma cleaner and intermediate frequency plasma cleaner:
The intermediate frequency plasma cleaner is an intermediate frequency. The 40KHz intermediate frequency power supply uses 16-bit microprocessor as the core, power electronic devices as the power output unit, and adopts new technologies such as digital frequency division, phase lock, waveform instantaneous feedback, SPWM pulse width modulation, IGBT output, etc. , And adopts a modular structure, with strong load adaptability, high efficiency, good stability, good output waveform quality, simple operation, small size, light weight, intelligent control, abnormal protection function, adjustable output frequency, fast output response , Strong overload capacity, fully isolated output, long life, good damage resistance. This kind of power controller is used on intermediate frequency ion equipment.
RF plasma cleaners use RF power, that is to say, the difference between our intermediate frequency plasma cleaner and RF plasma cleaner lies in the matching power they use. RadioFrequency, or RF for short. RF is RF current, which is an abbreviation for alternating high-frequency electromagnetic waves. The alternating current is called low-frequency current when it is below 1000 per second, and it is called high-frequency current when it is above 10000. The radio frequency current is this kind of high-frequency current. Therefore, we will easily distinguish between these two types of equipment.
Scan the QR code to read on your phone
TEL:0755-3367 3020 / 0755-3367 3019
E-mail:sales-sfi@sfi-crf.com
ADD:Mabao Industrial Zone, Huangpu, Baoan District, Shenzhen